Multi-Parameter holter monitor

Multi-Parameter holter monitor
Product Detailed
Multi-Parameter holter monitor 1.12" color TFT display 2.Support 12 channel waves,6 parameters 3.Unique voice alarm

Multi-Parameter holter monitor

Feature

12" clolr TFT display, support 12 channel waves,6 parametersUnique voice alarmMaximum 720 hours graphic and tabular trends of all parameters

up to 10000 NIBP review

200 alarm event review and 2 hours waveforms review

Standard configuration: ECG, SpO2, NIBP, RESP, TEMP

Optional: Dual IBP, CO2, IoC, Recorder

ECG

1. Lead mode: I II III,AVR.VL.AVF.V

2. Gain:          x0.25, x0.5, x1, x2

3. Heart Rate: 15-300bpm (Adult)   15-350bpm (Pediatric/Neonatal)

    Resolution:1bpm

    Accuracy: ±1%

4. Bandwidth: 0.05~130Hz    Monitor:        0.5~40Hz    Surgery:        1.0~20Hz

5. Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s

6. Pacemaker rejection:Yes

7. ST measurement Range: -0.8~+0.8mV

  Accuracy:  ±0.02mV or ±10% which is greater

SpO2

1. Measure range: 0-100%

2. Resolution: 1%

3. Accuracy: ±2%(70-100%); unspecified (<69%)

4. Pulse Rate: 20-250bpm    Resolution: 1bpm    Accuracy: ±3bpm

NIBP

1. Work Mode: Manual, Automatic, continuous

2. Unit: mmHg, kPa

3. Measure range:

                   Adult:     SYS:       40-280mmHg                                 DIA:       10-220mmHg                                 MEAN:   20-240mmHg               Pediatric:   SYS:       40-220mmHg                                 DIA:       10-160mmHg                                 MEAN:   20-170mmHg              Neonatal:   SYS:       40-135mmHg                                 DIA:       10-100mmHg                                 MEAN:   20-110mmHg

4. Resolution:    1mmHg

5. Accuracy: Maximum Mean error:±5mmHg;                     Maximum Standard deviation:8mmHg

6. Overpressure Protection: 0~300mmHg

RESP

1. Measure range: Adult                              0~120Brpm

                         Pediatric,Neonatal      0-150Brpm

2. Resolution: 1Brpm

3. Accuracy: ±2Brpm

TEMP

1. channels: 2

2. Measure range: 0-50°C

3. Resolution: 0.1°C

4. Accuracy: ±0.1°C(25°C-45°C) , ±0.2°C(other)

IBP(Optional)

1. channels:2

2. Measure range: -50~360mmHg

3. Accuracy: ±2% or ±1mmHg  which is greater

CO2(Optional)

1. Measure range: 0%~13%

2. Resolution: 1mmHg

3. Accuracy: ±2mmHg @ <5.0% CO2 (at ATPS)

4. Resp: 3-150rpm

IoC(Optional)

EEG sensitivity: ±475 uV

CMRR: >100dB

Input Impedance>50M ohm

IoC:0-100

EMG:0-100

ESR:0-100%

RECORDER (Optional)

1. Width:48mm

2. Speed:25/50mm/s

3. Channels:3

4. Bandwidth:

 0.05~130HzMonitor:      0.5~40HzSurgery:      1.0~20Hz

Pediatric,Neonatal      0-150Brpm

Input Impedance

Multi-Parameter holter monitor